Stefan Talu1, Rosalia Contreras-Bulnes2, Laura Emma Rodriguez-Vilchis2, Gonzalo Montoya-Ayala3
1Technical University of Cluj-Napoca, Faculty of Mechanical Engineering, Department of AET, Discipline of Descriptive Geometry and Engineering Graphics, 103-105 B-dul Muncii St., Cluj- Napoca 400641, Cluj, Romania.
2Universidad Autonoma del Estado de Mexico, Facultad de Odontologia, Centro de Investigacion y Estudios Avanzados en Odontologia, Mexico, C.P. 50130, Mexico.
3Universidad Nacional Autonoma de Mexico, Facultad de Odontologia, Laboratorio de Biologia Periodontal y Tejidos Mineralizados, Mexico.
Corresponding Author: Dr. Rosalia Contreras- Bulnes Universidad Autonoma del Estado de Mexico, Facultad de Odontologia, Centro de Investigacion y Estudios Avanzados en Odontologia, Mexico, C.P. 50130, Mexico. Tel: (52)7222124351,
E-mail: [email protected]
Received Date: 20 Jan 2016 Accepted Date: 01 Mar 2016 Published Date: 16 Mar 2016 Copyright © 2016 Contreras-Bulnes R
Citation: Stefan Talu, Contreras-Bulnes R, RodriguezVilchis LM and Montoya-Ayala G. (2016). Morphological Characterization of Human Dental Enamel Irradiated with Er:YAG Laser using the Statistical Functions. Mathews J Dentistry. 1(1): 005.
ABSTRACT
Purpose The aim of this study was to estimate the effect of irradiation with the Er:YAG laser on the surface nanomorphology of human dental enamel using the statistical functions. The surface nanomorphology was recorded by atomic force microscopy (AFM), and the data were estimated by statistical functions.
Materials and methods Two samples of human dental enamel were divided into two groups: a) group I was irradiated with the Er:YAG and no water irrigation with next 25.5 J/cm2 energy density; b) group II was the control (no laser irradiation or control). The nanomorphology changes were observed by AFM in contact mode, in air, on square areas of topography on the 1 µm * 1 µm. Based on AFM data and applying the computational algorithms, the statistical functions were plotted.
Results The local scale properties of human dental enamel at nanometric level were estimated with the statistical functions. The graphical results showed the local and global non-uniformity of the surface patterns. The one way analysis of variance (ANOVA) was performed (P < 0.05) to distinguish significant differences among the groups.
Conclusions The computational algorithm indicated that the surface nanomorphology differ significantly of these two groups. AFM and the statistical functions applied for surface roughness provide important information about the surface nanomorphology to characterize of non-uniform micro-distributions from the 3-D surface of the human dental enamel.
KEYWORDS
Atomic Force Microscopy; Human Dental Enamel; Er:YAG Laser Image Analysis, Statistical Functions; Surface Nanomorphology; Surface Roughness.
INTRODUCTION
Biominerals are a subset of the mineral kingdom, those created by living creatures. Among them, enamel is the hardest mineralized biological tissue, about 96 wt% (weight percentage) mineral in the form of crystallites of hydroxyapatite, 3 wt% water and and 1 wt% organic [1]. The enamel surface presents a variable appearance, exhibiting features such as aprismatic enamel, perikymata, prism-end markings, cracks, pits and elevations [2]. Furthermore, it has been reported that local factors in the enamel surface produce changes, such as those associated to oral habits, including toothbrushing, use of toothpastes, consumption of various beverages, as well as dental procedures between them, fluoride application, bleaching, etching agents and laser irradiation [3-13].
The Er:YAG laser is well absorbed by all biological tissues that contain water molecules, its use was approved in 1997 by the U.S. Food and Drug Administration (FDA) [14,15]. In dentistry, it is a versatile laser prescribed for the treatment of soft tissues and ablation of hard ones [14]. In addition, an early report suggested that enamel adjacent to the ablated area by Er:YAG laser irradiation exhibited an increase in acid resistance [16]. Several in vitro studies on smooth dental enamel surfaces concur that Er:YAG laser irradiation promotes caries prevention and produce morphological changes as revealed by SEM. However, the 3-D (three-dimensional) surface topographic features at nanometres level studied by Atomic force microscopy (AFM) have been scarcely evaluated [11-13, 17-21].
Application of the fractal and multifractal geometry has been used successfully in last years for numerical characterization of 3-D topography of human dental enamel surfaces [21-24].
It is known that, the fractal and multifractal analyses have also been used to quantitatively characterize the 3-D rough surfaces in the field of dental materials [25-29].
The main purpose of this study was to investigate the effect of irradiation with the Er:YAG laser on the surface nanomorphology of human dental enamel and the resulting changes in crystal structures. The sample 3-D surfaces were examined by atomic force microscopy (AFM) and the data were estimated by statistical functions.
MATERIAL AND METHODS
Tooth Selection and Sample Preparation
The protocol of this study was reviewed and approved by the Research and Ethics Committee at the Autonomous University of the State of Mexico (UAEM).
Caries-free bicuspid teeth extracted for orthodontic reasons from patients aged 15-17 years old, who reported no use of fluoride products other than fluoride toothpaste, were obtained with the patients informed consent. Teeth with caries, restorations, cracks, and defects in the structure or color of the enamel on the buccal surfaces or fluorosis were excluded.
Immediately after extraction, teeth were collected in 0.2 (wt/vol) thymol solution at 277 K for one month until the experiment was performed. Enamel fluorescence was evaluated with a laser fluorescence caries detection system DIAGNOdent® pen (DIAGNOdent, KaVo, Biberach, Germany), 2 teeth with sound enamel (values of 0-13, according to the manufacturer's specifications) were included in the study [30,31].
Each tooth was fixed with a thermoplastic epoxy resin (Allied High Tech Products, Rancho Dominguez, CA, USA) to a glass slide. Then, the crown was removed using a diamond disc (BesQual, New York, USA) mounted on a low-speed motor (Micromotor M2 Master, M25800011, Drillco Devices Ltd., Miami, FL, USA) under constant distilled water irrigation.
Afterwards, a diamond wheel saw (South Bay Technology, Inc., San Clemente, CA, USA) mounted on a cutter (South Bay Technology, Inc., USA) was used to obtain the samples under constant irrigation. One block (3 × 3 mm) from buccal surface was obtained from each tooth (one for group). Subsequently, all samples were rinsed (with deionized water) and dried at room temperature previous to AFM evaluation. The sample sizes was 1 × 1 mm.
Er:YAGLaser Irradiation
For the irradiation of the specimens, an Er:YAG laser system (Lumenis OPUS DUOTM Er:YAG + CO2, Yokneam, Israel) was employed, with a wavelength fixed at 2.94 µm, at an energy output from 100 to 200 mJ, frequency of 10 Hz, pulse duration of 250-400 msec, and an exit tip diameter from 1.0 to 1.3 mm.
As shown in Table 1, two slides of human dental enamel were divided into two groups: (n = 15, regions of interest (ROI) on each group. These ROI were selected through a random process from the AFM images obtained at next step.
Table 1: Details of the experimental and control groups tested in the study.
Groups (n = 15 regions of interest on each group) | Energyoutput | Diameter of the tip | Energy density | Water irrigation conditions |
I (laser irradiation) | 200 mJ | 1.0 mm | 25.5 J/cm2 | No irrigation |
II (no laser irradiation or control) | - | - | - | - |
The energy levels were calibrated by the calipers of the equipment. A power meter (LaserMate-P, Coherent Co., Santa Clara, CA) was employed to measure periodically the energy delivered. The surface was scanned once by hand (18 sec) with the sapphire tip of the laser perpendicular to it, at a working distance of 1 mm and with distilled water irrigation (5.0 mL/m).
Atomic Force Microscopy
All data were analyzed using the SPSS 18.0 statistical package (SPSS Inc., Chicago, IL, USA). The measurements were analyzed using the Kolmogorov-Smirnov test to assess the distribution of the data. Afterwards, the one way analysis of variance (ANOVA) was employed for comparison among groups; if significant differences were found, Bonferroni or Tamhane's T2 post-hoc tests were used, depending upon Levene's test of homogeneity of variance. In all statistical analysis, the level of significance was stated at P < 0.05.
Statistical Functions
For the complete description of the 3-D surface properties it is necessary to study higher order functions. Usually, secondorder statistical quantities observing mutual relationship of two points on the surface are employed. The statistical functions are namely the autocorrelation function (ACF), the height-height correlation function (HHCF), and the power spectral density function (PSDF) [32].
In our study we also used the radial ACF Gr(t) i.e. angularly averaged two-dimensional ACF, which of course contains the same information as the one-dimensional ACF for isotropic surfaces [32]. On the other hand, we used the radial PSDF Wr(K), i.e. angularly integrated two-dimensional PSDF, which of course contains the same information as the onedimensional PSDF for isotropic rough surfaces [32].
In our study, the computational analysis of the AFM files was performed on each region of interest (ROI), based on the original algorithm and the determined graphs were in correlation with ISO 25178-2: 2012 [32,33].
RESULTS
The representative 3-D AFM images, for scanning square areas of the samples from the two groups (Table 1), are shown in Figure 1, a, b: a) group I and b) group II. They are shown in 3-D mode, with the vertical height scale bar (in nanometers [nm]) displayed on the right side of the AFM image. Scanning square areas of 1 µm x 1 µm.
Figure 1: A set of representative AFM images (top and 3-D view), for scanning square areas of the samples from each group (Table 1), are shown in Figure 1, a, b: a) group I and b) group II. They are shown in 3-D mode, with the vertical height scale bar (in nanometers [nm]) displayed on the right side of the AFM image. Scanning square areas of 1 µm x 1 µm.
Group I has the most regular surface (Figure 1). This is qualitatively seen in Figure 1, a: image for group I has a lot of flat areas in comparison with group II.
Figure 2:The ACF, HHCF and PSDF functions for samples of Figure 1, in horizontal direction, for: a) group I; b) group II. Scanning square areas of 1 µm x 1 µm.
In Figure 3 are shown the ACF, HHCF and PSDF functions for samples of Figure 1, in vertical direction, for: a) group I; b) group II. Scanning square areas of 1 µm x 1 µm.
Figure 3: The ACF, HHCF and PSDF functions for samples of Figure 1, in vertical direction, for: a) group I; b) group II. Scanning square areas of 1 µm x 1 µm.
In Figure 4 are shown the radial ACF and radial PSDF functions for samples of Figure. 1, for: a) group I; b) group II. Scanning square areas of 1 µm x 1 µm.
Figure 4: The radial ACF and radial PSDF functions for samples of Figure 1, for: a) group I; b) group II. Scanning square areas of 1 µm x 1 µm.
As shown in Table 2, the computational algorithm indicated that surface nanomorphology differ significantly of these two groups.
Table 2: The basic properties of the height values distribution (including its variance, skewness and kurtosis) of the surface samples, for scanning square areas of 1 µm x 1 µm. Statistically significant difference for all values: P < 0.05.
The basic properties of the height values distribution of the surface samples | Group I | Group II |
---|---|---|
(Sa) [nm] | 15.8 | 12.3 |
(Sq) [nm] | 19.2 | 16.3 |
Skewness (Ssk) [-] | -1.20 | -1.65 |
Kurtosis (Sku) [-] | 0.94 | 4.30 |
Average inclination θ [°] | 24 | 49 |
Average inclination Ø [°] | -0.51 | -10.57 |
Relative projected area of hills, [%] | 58 | 60 |
DISCUSSIONS
AFM, the statistical surface roughness parameters, and multifractal analysis are useful tools for providing information about the 3-D surface nanomorphology of human dental enamel irradiated with an Er:YAG laser and optimal surface characteristics in order to characterize its structural 3-D microrelief [21].
There are no previous reports regarding to surface morphology evaluation of human dental enamel irradiated with Er:YAG laser, using the statistical functions.
After the analysis of AFM images from the two groups, it can be seen that each preparation protocol is associated with a specific topography. This type of topography is characterized by a significant heterogenity of sample surfaces (random distributions with elevations and local irregularities between nano-asperities) in a 3-D surface map, as a result from their preparation protocol process and it can be characterized by the statistical functions employed.
The surface of group I was more regular, comparative with the other group, it could be explained by melting and subsequent homogeneous recrystallization resulting from the heat generated by laser irradiation, with a degree of asymmetry A for group I closer to 0.7. Moreover, the surface nanomorphology of Er:YAG laser irradiation (under group I conditions) was the most regular when multifractal analysis was carried out [21].
On the other hand, group II (no irradiated enamel) have a large area of closed enamel prism in the surface, attributable to the natural organization of this tissue, with the minimum value of A. Also, two grooves were present in the no irradiated surface, observed as irregularities.
Investigation results indicated that the relationships between the surface micromorphology and the preparation protocol, and their determining are important, as the surface micromorphology has a significant effect on the surface features and clinical behaviour in the oral environment.
It should be taken into consideration that random distributions and localized irregularities also characterized the irradiated surface. Along these areal damages, some local damages could be detected. Final surface morphology of human dental enamel depends on the protocol type, and on a choice of optimal variant requires a deeper insight on the 3-D surface patterns quality.
CONCLUSION
Investigations carried out confirm that the surface roughness can be described by statistical functions and provide valuable information in characterization and comparison of 3-D microrelief peculiarities of human dental enamel.
These types of analyses provide a basis for additional research and analysis with 3-D methods in medical image analysis and computer graphics.
ACKNOWLEDGMENTS
The authors thank Dr. David Villanueva Jurado and Dr. Israel Ramirez Lopez, Maxillofacial Surgeons from the Clinica Odontologica Morelos, Instituto de Salud al Servicio del Estado de Mexico y Municipios (ISSEMYM), for their assistance with obtaining the samples. This project was financed by Universidad Autonoma del Estado de Mexico (UAEM) and Universidad Nacional Autonoma de Mexico (UNAM).
DECLARATION OF INTEREST
Neither author has a financial or proprietary interest in any material or method mentioned. All authors read and approved the final manuscript.
REFERENCES